Glossary
Search the abbreviations
Type an abbreviation or a word from its meaning. Use the chips to narrow by topic.
Treats wastewater from a single industrial unit so it can be reused or discharged within limits.
Read more →A shared plant that treats effluent from many industrial units in an estate or cluster.
Read more →Treats domestic sewage from buildings, campuses, towns or cities.
Read more →The polishing stage after biological treatment. It uses filtration, carbon, membranes or disinfection to make water fit for reuse.
Read more →A design in which no liquid effluent leaves the site. Water is recovered and the salts are solidified.
Read more →Sewage treated to a standard that allows reuse for flushing, landscaping or cooling.
Read more →Biological treatment combined with membrane filtration in place of a secondary clarifier.
Read more →A biological process where microbes grow as a film on plastic carriers that move freely in the tank.
Activated sludge treatment in one tank that runs in fill, react, settle and decant cycles.
An aerated tank of suspended microbial flocs that consume organic matter, followed by settling.
Fine air bubbles lift oil, grease and suspended solids to the surface, where they are skimmed off.
Read more →An evaporator that reuses vapour heat across several effects to concentrate brine. Common in ZLD.
Dries concentrated reject into a solid by spreading it as a thin film on a heated wall.
Oxygen that microorganisms use to break down organic matter in water. India reports BOD over 3 days at 27 °C; many other countries use 5 days at 20 °C.
The oxygen equivalent of the matter in water that can be chemically oxidised. It is always equal to or higher than BOD.
Solid particles carried in water that can be removed by filtration or settling.
Dissolved salts and minerals, in mg/L. TDS decides whether RO is needed and which type.
The concentration of biomass in an aeration tank, in mg/L.
The average time water stays in a tank. It equals tank volume divided by flow.
The average time biomass stays in the system, also called sludge age.
The organic load applied per unit of biomass. A key loading figure in biological design.
A measure of how well activated sludge settles.
Oxygen dissolved in water, in mg/L. Aeration is controlled to keep it in range.
A membrane process that pushes water through a semi-permeable membrane using pressure above the osmotic pressure, leaving most salts behind.
RO for seawater, which is typically about 30,000 to 45,000 mg/L TDS. It runs at high pressure.
Read more →RO for brackish water, typically about 1,000 to 10,000 mg/L TDS, at lower pressure than SWRO.
Read more →A membrane with very fine pores that removes suspended solids and bacteria. Often used ahead of RO or after biology.
Read more →A membrane with pores coarser than UF. It removes fine particles and some bacteria.
A membrane between UF and RO. It removes hardness and some organics, with partial salt rejection.
RO operated at pressures above conventional seawater RO to concentrate brine further.
Combines ion-exchange resin with an electric field to polish RO permeate into high-purity water, without chemical regeneration.
Read more →Water with its ions removed, usually by ion exchange.
Read more →Water with extremely low ions, organics and particles, used in power, pharma and electronics.
Read more →Water with dissolved minerals removed by ion exchange. Widely used as boiler feed.
Cleaning membranes or equipment in place with chemical solutions, without dismantling them.
A test of the fouling tendency of RO feed water. RO manufacturers usually ask for a low value, often below 5 and ideally below 3.
The pressure difference across a membrane. A rising TMP signals fouling.
An indicator of whether water tends to form scale or to corrode.
A pressure filter with layers of different media, such as anthracite, sand and garnet.
A pressure filter with two layers, typically anthracite over sand.
A pressure vessel filled with sand that removes suspended solids.
Removes chlorine, organics, taste and odour by adsorption on carbon.
A corrosion-resistant pressure vessel used for filters and softeners.
Inactivates microorganisms with UV-C light, with no chemical dosing.
Read more →Treats raw water to drinking-water or process-water quality.
Read more →The highest grade of pharmaceutical water, made to pharmacopoeia requirements.
A pharmacopoeia grade of water used in pharmaceutical manufacturing.
In a cooling tower, the ratio of dissolved solids in the circulating water to those in the make-up water.
A power station that raises steam from fuel. It needs make-up water, DM water and cooling water treatment.
Read more →A flow unit. 1 MLD equals 1,000 m³ per day, or about 41.7 m³ per hour.
A flow unit. 1 KLD equals 1 m³ per day.
A flow unit. 1 US MGD is about 3.785 MLD. 1 imperial MGD is about 4.546 MLD.
A contract where one contractor designs, supplies and builds the plant.
The contractor designs, builds and operates the plant for a set period and then hands it over. Some contracts add Own (DBOOT).
Running and maintaining a plant under contract.
Read more →A project model in which a private party builds or runs public infrastructure under agreed terms.
The national pollution control authority in India.
The state authority that issues consents and enforces discharge conditions.
Approvals from the State Pollution Control Board needed before building a plant and before running it.
Real-time effluent monitoring sent to the pollution control board. Required for many industrial categories.
A central scheme that supports urban water supply and sewerage projects.
The national programme for cleaning and protecting the river Ganga and its basin.
A municipal corporation, council or similar city authority.
The BIS specification for drinking water quality.
Read more →The BIS specification for packaged drinking water.
Often confused
ETP, CETP and STP: which is which?
| ETP | CETP | STP | |
|---|---|---|---|
| Full form | Effluent Treatment Plant | Common Effluent Treatment Plant | Sewage Treatment Plant |
| Treats | Industrial wastewater from one unit | Combined industrial effluent from many units | Domestic sewage |
| Typically owned by | The industrial unit | A society or company formed by member units | A building owner, developer or municipality |
| Main concern | Process-specific pollutants, reuse and compliance | Variable inlet load and member discipline | Organic load, nutrients and reuse of treated water |
| Read more | Effluent treatment plant | Common effluent treatment plant | Sewage treatment plant |
In short: an ETP serves one factory, a CETP serves a cluster of factories, and an STP serves people. The treatment steps overlap, but the pollutants and the contracts are different.
Flow units
Convert MLD, KLD, m³/h and MGD
Tenders and drawings mix units. Enter a value in any box.
Quick answers
Frequently asked questions
An ETP (Effluent Treatment Plant) serves one industrial unit and is owned and run by that unit. A CETP (Common Effluent Treatment Plant) serves many units in an estate or cluster, which pre-treat to an agreed inlet standard and send their effluent to the shared plant. The CETP then treats it to the discharge or reuse standard.
TTP stands for Tertiary Treatment Plant. It is the polishing step after biological (secondary) treatment and uses filtration, activated carbon, ultrafiltration or disinfection so that the water can be reused in the plant or discharged to a tighter limit.
SWRO is Sea Water Reverse Osmosis and BWRO is Brackish Water Reverse Osmosis. SWRO treats water of around 30,000 to 45,000 mg/L TDS at high pressure and typically recovers 35 to 50 percent. BWRO treats about 1,000 to 10,000 mg/L TDS at lower pressure and usually recovers a much higher share.
Multiply million US gallons per day by 3.785 to get million litres per day. For imperial gallons, multiply by 4.546. For example, 1 US MGD is about 3.785 MLD and 1 imperial MGD is about 4.546 MLD. 1 MLD equals 1,000 KLD or about 41.7 cubic metres per hour.
BOD measures the oxygen microorganisms use to break down biodegradable organic matter. COD measures the oxygen needed to chemically oxidise nearly all organic matter, including what bacteria cannot break down. COD is therefore always equal to or higher than BOD, and the BOD to COD ratio shows how biodegradable an effluent is.
ZLD stands for Zero Liquid Discharge. A ZLD plant treats effluent, recovers as much water as possible for reuse, and converts the remaining brine into solids, so no liquid effluent leaves the site.
Not sure which treatment your water needs?
Send your flow and water quality and an engineer will suggest a treatment route.
- Plain-language answer on which treatment suits your water
- Rough sizing from your flow and source
- A reply from an engineer, not a sales script
Prefer to talk? Call +91-90565-26208
Talk to an engineer
Thank you.
We have received your enquiry. Our team will contact you to discuss your plant and the next steps.
Prefer to talk first? WhatsApp us